Test ID COVID Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) RNA Detection, Varies
Advisory Information
Due to the non-specific clinical presentation of coronavirus disease (COVID-19) during the early stages of illness, testing for other respiratory tract infections (eg, influenza) may be warranted.
For the most up-to-date COVID-19 epidemiology and testing recommendations, visit https://www.cdc.gov/coronavirus/2019-ncov/index.html
Shipping Instructions
Ship specimens refrigerated (if less than 72 hours from collection to arrive at MCL) or frozen (if greater or equal to 72 hours from collection to arrive at MCL).
Specimen Required
Specimen Type: Nasopharyngeal (NP), oropharyngeal (OP; ie, throat), nasal mid-turbinate, or nares/nasal swab
Supplies:
-Swab, Sterile Polyester, 10 per package (T507)
-Dacron-tipped swab with plastic shaft is acceptable
Container/Tube: Universal transport media, viral transport media, or equivalent (eg, Copan UTM-RT, BD VTM, MicroTest M4, M4-RT, M5)
Media should not contain guanidine thiocyanate (GTC).
For more information on acceptable transport media, see https://www.fda.gov/medical-devices/emergency-situations-medical-devices/faqs-diagnostic-testing-sars-cov-2
Specimen Volume: Entire specimen with a minimum of 1.5 mL (maximum 3 mL) of transport media.
Collection Instructions:
1. Collect specimen by swabbing back and forth over nasal or pharyngeal mucosa surface to maximize recovery of cells. For more information on OP swab specimen collection, see COVID-19 Oropharyngeal Collection Instructions in Special Instructions.
2. NP and OP swab specimens may be combined at collection into a single vial of transport media but only one swab is required for analysis.
3. Swab must be placed into transport medium. Swab shaft should be broken or cut so that there is no obstruction to the sample or pressure on the media container cap.
4. Do not send in glass tubes, vacutainer tubes, or tubes with push caps.
5. Do not overfill with more than 3 mL total volume of media.
Specimen Type: Nasopharyngeal aspirate or nasal washings
Container/Tube: Sterile container
Specimen Volume: Minimum of 1.5 mL
Additional Information: Do not aliquot into viral transport media, glass tubes, vacutainer tubes, or tubes with push caps.
Specimen Type: Lower respiratory tract:
Sources: Bronchoalveolar lavage (BAL) fluid, bronchial washings, endotracheal aspirate, sputum
Container/Tube: Sterile container
Specimen Volume: Minimum of 1.5 mL
Additional Information: Do not aliquot into viral transport media, glass tubes, vacutainer tubes, or tubes with push caps.
Useful For
Detection of coronavirus disease 2019 (COVID-19) illness due to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2)
Recommended only for patients who meet current clinical and/or epidemiologic criteria defined by federal, state, or local public health directives: https://www.cdc.gov/coronavirus/2019-nCoV/hcp/clinical-criteria.html
Method Name
Real-Time Reverse Transcription Polymerase Chain Reaction (RT-PCR)
Reporting Name
SARS Coronavirus 2 RNA Detection, VSpecimen Type
VariesSpecimen Minimum Volume
See Specimen Required
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Varies | Frozen (preferred) | 14 days | |
Refrigerated | 72 hours |
Clinical Information
Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is a positive-sense, single-stranded RNA virus that causes coronavirus disease 2019 (COVID-19). Like other coronaviruses that infect humans, SARS-CoV-2 can cause both upper and lower respiratory tract infection. Symptoms can range from mild (ie, the common cold) to severe (ie, pneumonia) in both healthy and immunocompromised patients. SARS-CoV-2 transmission occurs primarily via respiratory droplets. During the early stages of COVID-19, symptoms maybe nonspecific and resemble other common respiratory tract infections, such as influenza. If testing for other respiratory tract pathogens is negative, specific testing for SARS-CoV-2 may be warranted.
SARS-CoV-2 is likely to be at the highest concentrations in the nasopharynx during the first 3 to 5 days of symptomatic illness. As the disease progresses, the viral load tends to decrease in the upper respiratory tract, at which point lower respiratory tract specimens (eg, sputum, tracheal aspirate, bronchoalveolar fluid) would be more likely to have detectable SARS-CoV-2.
Reference Values
Undetected
Interpretation
A "Detected" result indicates that severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) RNA is present and suggests the diagnosis of coronavirus disease 2019 (COVID-19). Test result should always be considered in the context of patient's clinical history, physical examination, and epidemiologic exposures when making the final diagnosis.
An "Undetected" result indicates that SARS-CoV-2 is not present in the patient's specimen. However, this result may be influenced by the stage of the infection, quality, and type of the specimen collected for testing. Result should be correlated with patient’s history and clinical presentation.
An "Indeterminate" result suggests that the patient may be infected with a variant SARS-CoV-2 or SARS-related coronavirus. Additional testing with an alternative molecular method may be considered if the patient does not have signs or symptoms of COVID-19.
An "Inconclusive" result indicates that the presence or absence of SARS-CoV-2 RNA in the specimen could not be determined with certainty after repeat testing in the laboratory, possibly due to RT-PCR inhibition. Submission of a new specimen for testing is recommended.
Clinical Reference
1. Zhu N, Zhang D, Wang W, et al: A novel coronavirus from patients with pneumonia in China, 2019. N Engl J Med. 2020;382(8):727-733. doi: 10.1056/NEJMoa2001017
2. Loeffelholz MJ, Tang YW: Laboratory diagnosis of emerging human coronavirus infections-the state of the art. Emerg Microbes Infect. 2020;9(1):747-756. doi: 10.1080/22221751.2020.1745095
3. Mohammadi A, Esmaeilzadeh E, Li Y, Bosch RJ, Li JZ: SARS-CoV-2 detection in different respiratory sites: a systematic review and meta-analysis. [published online ahead of print, 2020 Jul 18]. EBioMedicine. 2020;102903. doi: 10.1016/j.ebiom.2020.102903
4. Centers for Disease Control and Prevention. Â Overview of testing for SARS-CoV-2. Available at www.cdc.gov/coronavirus/2019-nCoV/hcp/clinical-criteria.html
5. Food and Drug Administration. FAQs on diagnostic testing for SARS-CoV-2. Available at www.fda.gov/medical-devices/emergency-situations-medical-devices/faqs-diagnostic-testing-sars-cov-2
Day(s) and Time(s) Performed
Monday through Sunday, Varies
Analytic Time
Same day/1 dayTest Classification
This test has received Emergency Use Authorization (EUA) by the U.S. Food and Drug Administration and is used per manufacturer's instructions in testing upper respiratory tract specimens, but it is modified from the manufacturer's instructions with a bridging study in testing lower respiratory tract specimens. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.CPT Code Information
U0003
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
COVID | SARS Coronavirus 2 RNA Detection, V | 94500-6 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
608827 | SARS-CoV-2 RNA | 94500-6 |
CVDS | SARS-CoV-2 Specimen Source | 31208-2 |
CRACE | Patient Race | 72826-1 |
CETHN | Patient Ethnicity | 69490-1 |
Special Instructions
Forms
If not ordering electronically, complete, print, and send a General Request (T239) with the specimen.